Air Conditioner Cooling Outdoor Telecom Cabinet 19 Inch Rack Enclosures

Brand Name : ESTEL
Model Number : ET9090170
Certification : ISO9001, CE, 3C, FCC, TLC, IP55
Place of Origin : Shenzhen, China (Mainland)
MOQ : 1 set
Price : negotiation
Payment Terms : L/C,D/A,T/T, Western Union, Paypal, etc
Supply Ability : 5,000 sets per month
Delivery Time : 15-20 working days
Packaging Details : wooden case
External Size : H×W× 1700×900×900mm
Color : grey (support custom made)
Protection Level : IP55
Cooling Capaciyt : 1500W(air conditioner)
Contact Now

Air Conditioner Cooling Outdoor Telecom Cabinet 19 Inch Rack Enclosures


Quick Details


Place of Origin: Shenzhen, China (Mainland)External Dimension H×W×D 1700×900×900mm

Brand Name: ESTEL

Structure: double wall, with insulation, sandwich structure.

Model Number: ET9090170

Cabinet Layout: one compartment, for installing 19” equipment

Product Name: Outdoor Telecom Equipment Cabinet

Cabinet Lock: anti-theft three point lock
Certification: ISO9001, CE, 3C, FCC, TLC, IP55

Protection Level: IP55

Application: outdoor telecom base stationCable Entry: at cabinet bottom
Material: galvanized steelIllumination: DC48V LED lamp

Heat Insulation: PEF

Grounding Protection: copper bar

Color: grey (support custom made)

Cooling: AC220V air conditioner and DC48V fans

Coating: anti-corrosion outdoor powder coating

Accessories Options: PDU, environment monitoring system

Payment & Shipping Terms:


Minimum Order Quantity:1 set
Price:negotiation
Payment Terms:L/C,D/A,T/T,Western Union, Paypal, etc
Supply Ability:5,000 sets per month
Delivery Time:15-20 working days
Packaging Details:wooden case

1. Specifications

(1) Technical Parameters


ItemTypeTechnical Parameter
StructureDimensionExternal Dimension H×W×D 1700×900×900mm
LayoutOne compartment
Equipment Installation Method19” standard rack
DoorWith one front door, and anti-theft three point lock for outdoor cabinet (support padlock)
Material

1.Galvanized steel;

2.Double wall, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with heat insulation between two walls.

StructureAssembled
Ingress ProtectionIP55
Temperature ControlCoolingAC220V Air Conditioner and DC48V fans
LightingLED lamp48V LED lamp
TemperatureTemperatureWorking Temperature: -40°C ~ +55°C
Storage Temperature: -50°C ~ + 70°C
Transport Temperature: -50°C ~ +70°C
HumidityRelative Humidity5% ~ 100%
PressureAir Pressure62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Radiation IntensitySolar Radiation Intensity1124 × (1±5%)W/m2

(2) Accessories List


No.ItemQuantityUnitSpecs
1Outdoor Telecom Cabinet1Set

(1) External Dimension H×W×D 1700×900×900mm

(2) One compartment;

(3) With one front door, and anti-theft three point lock for outdoor cabinet (support padlock)

(4) Material: galvanized steel; double wall, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with 40mm PEF heat insulation between two walls

2Air Conditioner1Set

Power Supply: AC220V 50Hz

Cooling Capacity: 1500W

Model: TC06-150JFH/01

3Fan2PC12038, DC48V
4Power Distribution Unit1Set

Grade B Lightning Proof 60KA*1

AC Input: 63A/2P *1;

AC Output: 63A/1P *2;

AC Output: 32A/1P*2;

AC Output: 16A/1P*4;

Maintenance Socket *1;

Height: 4U

5Environment Monitoring System1Set

1× environment monitoring unit;

1× smoke sensor,

1×water sensor,

1× temperature&humidity sensor,

2× door sensor

6LED Lamp1DC48V
7Package1SetWooden Case

2. Application Scope


The Outdoor Telecom Cabinet is mainly used in communication base station, such as 4G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc.


3. Cabinet Introduction

3.1 Cabinet Material


The cabinet is made of galvanized steel, with double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm. There are heat insulation between inner wall and outer wall. The insulation material is 40mm PEF. The cabinet is assembled type.

3.2 Cabinet Structure


The cabinet is equipment cabinet, including 19” equipment installation rack, with air conditioner on cabinet door.

3.3 Cabinet Door and Lock


The cabinet door uses embedded structure. The door opening angle is larger than 110°and the door limit device can limit the opening angle. The lock is theftproof three point lock, supporting padlock. Each cabinet door include open door sensor, working together with the environment monitoring unit.

4. Features


4.1 The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment.

4.2 The cabinet cooling uses air conditioner.

4.3 Including -48VDC illumination lamp.

4.4 The cabinet includes power and environment monitoring unit, which can send power failure alarm, door open alarm, temperature and humidity alarm, smoke alarm, water alarm etc.

4.5 The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. At the bottom of the cabinet, there are entrance holes individually for power cable, signal cable and optical cable.

4.6 All the cables, sealing and heat insulation used in the cabinet are made from flame retardant materials.

4.7 The cabinet uses assembled structure, easy for installation.

4.8 The cabinet includes 19” standard installation rack.


5. Technical Specs

  • Applicable environment conditions:

Environment temperature: -40°C ~ + 70°C

Environment humidity (RH): ≤95% (at + 40°C)

Air pressure: 62kPa ~ 102kPa

  • Material: good quality galvanized steel
  • Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.
  • Cabinet load bearing: ≥600kg
  • Ingress protection: IP55
  • Flame retardance: comply with GB5169.7 test A
  • Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2X104M/500V(DC).
  • Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.
  • Mechanical strength: each surface can bear upright pressure>980N; after the door is open, its outer end can bear upright pressure >200N.

Dimension Diagram


Cabinet External Dimension (W×D×H): 900×900×1700mm.


6. Sensors Installation

6.1 LED lamp, smoke sensor and door sensor are installed at the top of the cabinet.


6.2 Water sensor is installed at the bottom of the cabinet.



6.3 Temperature and humidity sensor is installed at the side inside the cabinet.



7. Wire Routing Design


Feeder cable and other external cables all use bottom wiring method.


8. Grounding Protection


  • The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.
  • The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.
  • Protective earthing of other equipments inside the cabinet should be connected to the grounding bar.

9. Theft Proof Design

9.1 Door lock theft proof design

  • Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock” class B requirement, supporting padlock.

  • Three point lock

9.2 Connection and Fastening

  • Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
  • Door hinges use inner hinge mode.

9.3 Appearance and Surface Treatment


Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.


10. Cabinet Installation


10.1 Position of installation holes at cabinet base are as follows:



Diagram 1


10.1 Users prefabricate concrete base.

10.2 Pre-embed 4pcs M10×120 anchor bolts on the concrete base. Distance between bolts are as that in diagram 1. Bolt exposed height is 40mm. Put the cabinet on the concrete base, align anchor bolts, then screw on nuts, and tighten them with wrench.

10.3 According to site situation, put the cabinet on the concrete base with forklift, crane or manually, and fix it on the concrete base with bolts.


11. PDU Principle Diagram


12. Packing and Shipping



Our Delivery Agent


The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.


13. Our Contact Information


Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

lxf.estel@hotmail.com
Skype: fiona.liang10


Product Tags:

Telecom Equipment Cabinet

      

Outdoor Communication Cabinets

      
China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

Air Conditioner Cooling Outdoor Telecom Cabinet 19 Inch Rack Enclosures Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Tianjin Estel Electronic Science and Technology Co.,Ltd
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0